Solutions

Act on the exposed surface, with the right solution for each substrate

Act directly on surfaces exposed to heat, with a solution suited to the substrate: roofs, cladding, glazing, façades, tanks, equipment and textiles.

Understand

What is radiative cooling?

Passive radiative cooling uses a natural phenomenon: every warm surface emits energy as infrared radiation. When this radiation escapes into space through the 8–13 µm atmospheric window, the surface releases some of its heat. Cooleco solutions combine high solar reflectance with high infrared emittance to limit heat gain and reduce the thermal load of buildings.

1 · Reflect

solar radiation to limit surface heat gain.

2 · Emit

high levels of infrared radiation within the 8–13 µm atmospheric window.

3 · Reject

some heat into space, without any active energy input.

Performance varies with climate, geometry, orientation, substrate, insulation level and building use. Unless explicitly stated otherwise, the figures on this website come from tests and reference cases provided by our partners and must be confirmed by a project-specific study. The radiative properties of SolCold products are an exception: they have been measured by LNE and by TESA SE.

Choosing the right solution

Specification by use, substrate and energy objective

Choosing a solution by situation
SituationRecommended solutionMain objective
Metal roof or claddingFR Series or Polar 90Reduce surface temperature and air-conditioning load
Glazed façade or glass roofT SeriesReduce solar gain through glazing
Electrical and telecom cabinetsFR SeriesLimit temperature peaks and equipment cooling runtime
Tanks, silos and reservoirsFR Series or Cooleco CoatingsProtect products, reduce pressure and heat gain
Architectural façadeCooleco W3111-14Cooling and surface protection
Blinds, textiles and outdoorCooleco Textile SeriesComfort and solar protection without power
Low-inertia substrateGlacier 110Aim for a surface close to air temperature (TESA SE calculation)
Requirement for third-party performance evidencePolar 90 or Glacier 110Specification supported by an SRI measured by two laboratories (LNE, TESA SE)

Polar 90 and Glacier 110, LNE and TESA SE data: measurements and calculations

Polar 90 and Glacier 110, LNE and TESA SE data: measurements and calculations
PropertyPolar 90Glacier 110ASTM E1980 reference white
Solar reflectance (LNE)87.7%89.5%80%
Emittance at 25 °C (LNE)85.5%83.4%90%
LNE SRI (convection 12 W/m²K)110.5112.8100
TESA SRI (same conditions)114121100
Calculated surface temperature (TESA)39.5 °C36.7 °C44.6 °C
Difference from air temperature (TESA calculation)+2.6 K−0.2 K+7.7 K
Reflected solar energy877 W/m²895 W/m²800 W/m²

With an engineering firm, insurer or public owner, the SRI measured by LNE and by TESA SE is the strongest data in our range: it is standardised and comparable. The FR, T, Textile and Coatings ranges rely on partner data, to be confirmed by tests if the contract requires it.

Energy study

We start with air-conditioning consumption, exposed surface areas, surface temperatures and the occupancy profile.

Avoided cost

Estimated annual saving = cooling consumption × energy price × reduction rate.

Additional benefits

Comfort, reduced peak power demand, less thermal ageing and protection of goods.

Applications

Where these solutions are useful

Oil tanks

Reducing wall and contents temperatures can lower internal pressure, limit evaporation losses and improve operational safety during hot weather.

Sensitive warehouses

Radiative solutions are particularly suited to buildings where preservation depends on stable temperatures: food, beverages, pharmaceuticals or sensitive materials.

Logistics roofs

Across large roof areas, every degree of heat gain avoided at the envelope helps reduce the building’s overall thermal load. Bituminous waterproofing is not validated to date.

Silos and storage

Highly exposed roofs and curved walls can be treated with film or coating, depending on the substrate and geometry.

Electrical and telecom enclosures

Limit internal heat gain, protect electronics and reduce active cooling. Other partner tests indicate significantly shorter air-conditioner operating periods in technical rooms after treatment of exposed surfaces.

Data centres and server rooms

Reduce heat gain through the envelope and the load on cooling systems. We can size a solution according to dissipated power, substrate and solar exposure.

Schools and town halls

Improve comfort in classrooms and halls with limited or no air conditioning during hot weather.

Batteries, photovoltaics and cooling

Treat enclosures, panels and technical equipment exposed to sunlight.

Shops and large retail

Limit heat gain through the roof and glazing, and the air-conditioning load in hot weather.

Food refrigeration

Reduce heat gain on the envelope and exposed equipment, to ease the load on refrigeration units.

Outdoor air-conditioning units

Treat casings exposed to the sun to limit their heating.

Airports and stations

Treat highly exposed passenger bridges, glass roofs and large roofs.

Context

Heat is becoming an operational constraint

+1.55 °C
global mean anomaly in 2024 compared with 1850-1900
WMO, January 2025
10 years
2015-2024, the ten warmest years on record
WMO, January 2025
20%
of electricity used in buildings already goes to air conditioners and fans
IEA, The Future of Cooling, 2018
×3
possible global cooling demand by 2050 without efficiency action
IEA, The Future of Cooling, 2018

Sources: World Meteorological Organization (WMO) · International Energy Agency (IEA). Peak cooling demand coincides with the hours when the electricity grid is under the greatest pressure.

What it means for businesses

  • Maintain business continuity during hot weather.
  • Protect staff, stocks and sensitive equipment.
  • Reduce peak power demand and air-conditioning bills.
  • Adapt existing buildings with minimal intervention.

Two complementary approaches

  • Reduce heat gain: treat the envelope before heat enters the building.
  • Optimise equipment: sizing, control and efficiency of cooling systems.

Which solution for your site?

Surface area, substrate, location and consumption: we estimate your building’s potential.

Request a study