Act on the exposed surface, with the right solution for each substrate
Act directly on surfaces exposed to heat, with a solution suited to the substrate: roofs, cladding, glazing, façades, tanks, equipment and textiles.
What is radiative cooling?
Passive radiative cooling uses a natural phenomenon: every warm surface emits energy as infrared radiation. When this radiation escapes into space through the 8–13 µm atmospheric window, the surface releases some of its heat. Cooleco solutions combine high solar reflectance with high infrared emittance to limit heat gain and reduce the thermal load of buildings.
1 · Reflect
solar radiation to limit surface heat gain.
2 · Emit
high levels of infrared radiation within the 8–13 µm atmospheric window.
3 · Reject
some heat into space, without any active energy input.
Performance varies with climate, geometry, orientation, substrate, insulation level and building use. Unless explicitly stated otherwise, the figures on this website come from tests and reference cases provided by our partners and must be confirmed by a project-specific study. The radiative properties of SolCold products are an exception: they have been measured by LNE and by TESA SE.
One logic, one solution per substrate
Polar 90
solar reflectance
LNE measurement, August 2026
A white self-adhesive film for roofs, cladding, tanks and silos.
€45.00/m²
Glacier 110
solar reflectance
LNE measurement, August 2026
A film for low-inertia substrates, where every degree counts.
€80.00/m²
FR Series
solar reflectance, FR5B100
Partner data
Reflective films for exposed opaque surfaces.
€35.80/m²
T Series
solar energy rejected, T13300W
Partner data
Films to control the sun through glazing.
from €29.80/m²
Coatings
reflectance, metal system
Partner data
Multi-layer coatings that protect the substrate and limit heating.
from €13.50/m²
Textile Series
solar reflectance, TP500
Partner data
Technical fabrics for blinds, covers and shading.
from €5.54/m
Specification by use, substrate and energy objective
| Situation | Recommended solution | Main objective |
|---|---|---|
| Metal roof or cladding | FR Series or Polar 90 | Reduce surface temperature and air-conditioning load |
| Glazed façade or glass roof | T Series | Reduce solar gain through glazing |
| Electrical and telecom cabinets | FR Series | Limit temperature peaks and equipment cooling runtime |
| Tanks, silos and reservoirs | FR Series or Cooleco Coatings | Protect products, reduce pressure and heat gain |
| Architectural façade | Cooleco W3111-14 | Cooling and surface protection |
| Blinds, textiles and outdoor | Cooleco Textile Series | Comfort and solar protection without power |
| Low-inertia substrate | Glacier 110 | Aim for a surface close to air temperature (TESA SE calculation) |
| Requirement for third-party performance evidence | Polar 90 or Glacier 110 | Specification supported by an SRI measured by two laboratories (LNE, TESA SE) |
Polar 90 and Glacier 110, LNE and TESA SE data: measurements and calculations
| Property | Polar 90 | Glacier 110 | ASTM E1980 reference white |
|---|---|---|---|
| Solar reflectance (LNE) | 87.7% | 89.5% | 80% |
| Emittance at 25 °C (LNE) | 85.5% | 83.4% | 90% |
| LNE SRI (convection 12 W/m²K) | 110.5 | 112.8 | 100 |
| TESA SRI (same conditions) | 114 | 121 | 100 |
| Calculated surface temperature (TESA) | 39.5 °C | 36.7 °C | 44.6 °C |
| Difference from air temperature (TESA calculation) | +2.6 K | −0.2 K | +7.7 K |
| Reflected solar energy | 877 W/m² | 895 W/m² | 800 W/m² |
With an engineering firm, insurer or public owner, the SRI measured by LNE and by TESA SE is the strongest data in our range: it is standardised and comparable. The FR, T, Textile and Coatings ranges rely on partner data, to be confirmed by tests if the contract requires it.
Energy study
We start with air-conditioning consumption, exposed surface areas, surface temperatures and the occupancy profile.
Avoided cost
Estimated annual saving = cooling consumption × energy price × reduction rate.
Additional benefits
Comfort, reduced peak power demand, less thermal ageing and protection of goods.
Where these solutions are useful
Oil tanks
Reducing wall and contents temperatures can lower internal pressure, limit evaporation losses and improve operational safety during hot weather.
Sensitive warehouses
Radiative solutions are particularly suited to buildings where preservation depends on stable temperatures: food, beverages, pharmaceuticals or sensitive materials.
Logistics roofs
Across large roof areas, every degree of heat gain avoided at the envelope helps reduce the building’s overall thermal load. Bituminous waterproofing is not validated to date.
Silos and storage
Highly exposed roofs and curved walls can be treated with film or coating, depending on the substrate and geometry.
Electrical and telecom enclosures
Limit internal heat gain, protect electronics and reduce active cooling. Other partner tests indicate significantly shorter air-conditioner operating periods in technical rooms after treatment of exposed surfaces.
Data centres and server rooms
Reduce heat gain through the envelope and the load on cooling systems. We can size a solution according to dissipated power, substrate and solar exposure.
Schools and town halls
Improve comfort in classrooms and halls with limited or no air conditioning during hot weather.
Batteries, photovoltaics and cooling
Treat enclosures, panels and technical equipment exposed to sunlight.
Shops and large retail
Limit heat gain through the roof and glazing, and the air-conditioning load in hot weather.
Food refrigeration
Reduce heat gain on the envelope and exposed equipment, to ease the load on refrigeration units.
Outdoor air-conditioning units
Treat casings exposed to the sun to limit their heating.
Airports and stations
Treat highly exposed passenger bridges, glass roofs and large roofs.
Heat is becoming an operational constraint
Sources: World Meteorological Organization (WMO) · International Energy Agency (IEA). Peak cooling demand coincides with the hours when the electricity grid is under the greatest pressure.
What it means for businesses
- Maintain business continuity during hot weather.
- Protect staff, stocks and sensitive equipment.
- Reduce peak power demand and air-conditioning bills.
- Adapt existing buildings with minimal intervention.
Two complementary approaches
- Reduce heat gain: treat the envelope before heat enters the building.
- Optimise equipment: sizing, control and efficiency of cooling systems.
Which solution for your site?
Surface area, substrate, location and consumption: we estimate your building’s potential.